As part of our enviornment strategy, we are issuing a call for tenders to replace doors at the
InterContinental Hotel. The renovation job requires removing existing apertures and installing new ones
with the minimum characteristics described below. Due to management purposes, the pricing must be
divided into materials/parts and labour separately. The labour figure shall be a combined figure for
manufacturing, removal and installation.
Measurements
Typology | Width | Height | Quantity |
2LeafSlidingDoorwithSidesFixed | 1980mm | 2110mm | 403 |
4LeafSlidingDoorwithSidesFixed | 3760mm | 2110mm | 34 |
MinimumTechnicalRequirements
Ug | 1 | Double Glaze Laminated Solar / Argon / Laminated Clear |
Uw | 1.8 | |
dBofGlass | Option 1 – Rw 35 | Option 2 – Rw 42 |
WaterTightness | E750 | |
AirPermeability | 4 | |
ResistancetoWindload | 5C | |
Colour | RAL 9005 / Black | |
ExtraFittings | 1) Concealed Sensor for Air Conditioning | |
2) Child Lock, separate from the handle and installed at an elavated height | ||
Removals | Aluminium removed shall be recycled; thus, a recycling certificate shall be provided during the project. |
Certifications
To provide supplier certifications and pictures for the above requirements
Notes
Due to logistics concerns, the outer door frame must be assembled on-site rather than delivered as a whole.
Project
The project will be completed in twelve months, where the hotel will be in normal operating conditions.
Send your quotation to [email protected] by no later than the 30th of Septmber.